Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads
The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the MC4 PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line.
Key functions of the solar clamp meter and MC4 test leads:
View voltage and current simultaneously with the meter's dual display
IP54 rated meter, ideal for work outdoors including PV panel testing
DC power measurement, showing readings in kVA
Logging and reporting of test results via Fluke Connect software
MC4 leads comply to IEC / EN 61010-031
Additional information
fb_visibility
yes
Weight
4 oz
Dimensions
5 × 6 × 12 in
Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter
General
Maximum voltage between any Terminal and Earth Ground
AC
1000 V
DC
1500 V
Batteries
2 AA IEC LR6 alkaline
Display
Dual display with backlight
Automatic Power Off
20 minutes
Electrical
Accuracy
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients
Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)
2.5 @600.0 A
3.0 @500.0 A
1.42 @999.9 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range
999.9 A
2500 A
Resolution
0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy
3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz)
2.5 @1400 A
3.0 @1100 A
1.42@2500 A
Add 2 % for C.F. >2
Position Sensitivity
Distance from Optimum
i2500-10 Flex
i2500-18 Flex
Error
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
±0.5 %
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
±1.0 %
C
1.4 in (35.6 mm)
2.5 in (63.5 mm)
±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % RD + 5 digits[1]
[1] When using the ZERO (B) function to compensate for offsets.
AC Voltage
Range
600.0 V
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1 % RD + 5 digits (20 Hz to 500 Hz)
DC Voltage
Range
600.0 V
1500 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy
1 % RD + 5 digits
mV dc
Range
500.0 mV
Resolution
0.1 mV
Accuracy
1 % RD + 5 digits
Amps Frequency: Jaw
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % RD + 5 digits
Trigger Level
5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % RD + 5 digits
Trigger Level
5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % RD + 5 digits
Trigger Level
5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power
Range
600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution
0.1 kVA
1 kVA
Accuracy
2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance
Range
600.0 Ω
6000 Ω
60.00 kΩ
Resolution
0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy
1 % RD + 5 digits
Capacitance
Range
100.0 μF
1000 μF
Resolution
0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy
1 % RD + 5 digits
Inrush Trigger Level
5 A
Mechanical
Size (L x W x H)
281 mm x 84 mm x 49 mm
Weight (with batteries)
520 g
Jaw Opening
34 mm
Flexible Current Probe Diameter
7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental
Operating Temperature
-10 °C to 50 °C
Storage Temperature
-40 °C to 60 °C
Operating Humidity
Non condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating Altitude
2000 m
Storage Altitude
12 000 m
Ingress Protection (IP) Rating
IEC 60529: IP54 non-operating
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)
Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
General
IEC 61010-1, Pollution Degree 2
Measurement
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radio frequency certification
FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless Radio Frequency Range
2400 MHz to 2483.5 MHz
Output Power
<100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address: